APPENDICES
PARAMETER
This is the basic data used in positioning.
Parameters are determined by the machine
side design, so subsequent changes of
parameters must be accompanied by changes
in the machine design.
Data cannot be written during positioning. The
initial parameter values are written by the
maker.
POSITION CONTROL
This is mainly the control of position and
dimension, such as in fixed-dimension feed,
positioning, numerical control, etc. This is
always controlled with feed pulses. There is
also speed control.
POSITION LOOP GAIN
This is the ratio of the deviation counter droop
pulse count to the command speed (pulse/s).
Command speed
Position
=
loop gain
Droop pulse count
The position loop gain can be set with the
servo amplifier. Raise the gain to improve the
stopping accuracy. However, overshooting will
occur if the position loop gain is raised too far,
and the operation will become unstable.
If the position loop gain is lowered too far, the
machine will stop more smoothly but the
stopping error will increase.
POSITION LOOP MODE
This is one servo control mode used in
positioning. It is a mode for carrying out
position control. The other servo control
modes are the speed loop mode for carrying
out speed control, and the torque loop mode
for carrying out torque control (current control).
Servo amplifier
Droop pulses
Pulse train
Posi-
Speed
tion
control
control
Speed feedback
Position feedback
(1/s)
Servomotor
Cur-
M
rent
Inverter
control
Current feedback
Interface
PLG
Appendix - 42
POSITIONING
Accurately moving the machine from a point to
a determined point. The distance, direction,
speed, etc., for that movement are designated
by the user. Positioning is used in operations
such as cutting sheets, drilling holes in plates,
mounting parts on a PCB, and welding.
Positioning is also used with robots.
POSITIONING COMPLETE SIGNAL
This is a signal that occurs when the
positioning is complete. A timer set beforehand
starts when this signal is output, and the
machine movement stops for that time.
This signal is used to turn OFF the positioning
start signal.
Dwell time
Positioning
POSITIONING DATA
This is data for the user to carry out
positioning. The No. of points to which
positioning is carried out (the No. of
addresses) is designated by the user. In the
AD75, this is a maximum of 600 points.
As a principle, positioning is executed in the
order of the data Nos.
POSITIONING PARAMETER
This is basic data for carrying out positioning
control. Types of data include control unit,
movement amount per pulse, speed limit
value, upper and lower stroke limit values,
acceleration/deceleration time, positioning
method, etc.
Parameters have an initial value, so that value
is changed to match the control conditions.
MELSEC-A
Positioning complete
signal
Different type of work
Time