S3C2416X RISC MICROPROCESSOR

5.31 FORCE EVENT REGISTER FOR AUTO CMD12 ERROR STATUS

Register
FEAER0
0X4AC00050
FEAER1
0X4A800050
The Force Event Register is not a physically implemented register. Rather, it is an address at which the Auto
CMD12 Error Status Register can be written.
Writing 1: set each bit of the Auto CMD12 Error Status Register
Writing 0: no effect
D15 D12
Name
Bit
[15:8]
[7]
[6:5]
[4]
[3]
[2]
[1]
[0]
Address
R/W
WO
WO
Force Event for Command Not Issued By Auto CMD12 Error
1 = Interrupt is generated
0 = No Interrupt
Force Event for Auto CMD12 Index Error
1 = Interrupt is generated
0 = No Interrupt
Force Event for Auto CMD12 End Bit Error
1 = Interrupt is generated
0 = No Interrupt
Force Event for Auto CMD12 CRC Error
1 = Interrupt is generated
0 = No Interrupt
Force Event for Auto CMD12 Timeout Error
1 = Interrupt is generated
0 = No Interrupt
Force Event for Auto CMD12 Not Executed
1 = Interrupt is generated
0 = No Interrupt
Description
Force Event Auto CMD12 Error Interrupt
Register Error Interrupt (Channel 0)
Force Event Auto CMD12 Error Interrupt
Register Error Interrupt (Channel 1)
Description
HSMMC CONTROLLER
Reset Value
0x0000
0x0000
Initial Value
0x0
0
0
0
0
0
0
0
20-69