ESS Maintenance Object

Error Log Entries and Test to Clear Values

Table 14: ESS Error Log Entries
Error
Aux
Type
Data
)
1
(a
)
257
(b
)
513
(c
Notes:
a. Error Type 1: This error only applies to an ESS server.
When an ESS server assumes control of an IPSI Port Network, this error is generated and
logged.
The following steps may be followed to investigate and attempt to retire the alarm:
1. Avaya Fault and Performance Management can be used to obtain a network view of the
Enterprise Survivable Server configuration. Note any network fragmentation or media
server outages (Main server or ESS server).
2. Use the SAT command status ess port-network to identify which ESS Cluster IDs
each Port Network (IPSI) is connected to. This command may be executed at either a
Main server or ESS server. With a fragmented network it may be necessary to execute
this command at each media server in the system configuration to acquire a complete
view of IPSI connectivity.
3. Using either Avaya Fault and Performance Management or SAT sessions to each media
server determine the extent of any server or network outages.
174 Avaya Enterprise Survivable Servers (ESS) Users Guide
Associated Test
None
None
None
Alarm
On/Off
Test to Clear Value
Level
Board
MAJ
OFF
ESS server controlling Port
Network(s).
Resolve any server and/or
network problems. Schedule or
initiate an on-demand switch
back of Port Networks to the
Main server.
MIN
OFF
ESS server is not registered.
Resolve any server and/or
network problems.
MIN
OFF
Connection not established
between ESS server and IPSI.
Resolve any ESS server and/or
network problems. Use the PING
command to verify connectivity
to IPSI circuit packs.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents