An-Ln-Pt (Analog Line Port) - Avaya DEFINITY Server CSI Maintenance Manual

Table of Contents

Advertisement

AN-LN-PT (Analog Line Port)

AN-LN-PT (Analog Line
Port)
MO Name (in Alarm Log)
AN-LN-PT
AN-LN-PT
1.
UU is the universal cabinet number. C is the carrier designation (A, B, C, D, or E). SS is the number
of the slot in which the circuit pack resides (01 to 21). pp is the two digit port number (01, 02, etc.).
The TN793B/TN2793B Analog Line circuit pack (w/ Caller ID), and the TN797
Analog Trunk and Line circuit pack both support this Maintenance Object.
The TN793B/TN2793B Analog Line circuit pack (w/ Caller ID) provides 24 ports
for voice terminals and supports both on-premises and off-premises analog voice
terminals.
The TN797 Analog Trunk and Line circuit pack provides 8 ports, each of which
may be administered in any of several ways, as described in maintenance object
TR-LN-BD.
NOTE:
The TN793B/TN2793B analog line circuit pack supports analog data
modules. When assigned, analog data modules provide access to the
NetPkt (TN2401/TN794 circuit pack) data ports. To activate an analog data
module, assign the port location on the data form and connect a modem to
the port. The analog data module can be used for connection to a CDR
output, or other adjuncts as needed. These ports are tested the same as all
other analog ports on the circuit pack.
Ringing caused by maintenance testing
Test #48 may cause some terminal equipment to ring briefly during daily
maintenance. If this disturbs the user or the phone equipment, to disable Test #48
use change station
releases, this will also disable Tests #6, 7, 35, 47, and 161.
555-233-119
Alarm Level
Initial Command to Run
MIN
test port UUCSSpp l
WRN
test port UUCSSpp sh
and set the Tests field to n. On some software
extension
1
Full Name of MO
Analog Line Port
Analog Line Port
Issue 5 October 2002
675