Canister Status Led Indicators; Tip Wipe Height Adjustment Wheels - Stratasys K6 Series User Manual

3d production system
Table of Contents

Advertisement

CANISTER STATUS LED INDICATORS

There is one colored status LED above each canister. This LED indicates the canister condition for each
canister bay
(Figure
3-7). LEDs states are as follows:
Off: No canister detected, or a canister is present but filament has not been fed into the canister
drive.
Green – Slow Flashing (ready state): Filament has been fed into the canister drive but is not loaded
to the head; canister can be unloaded if necessary.
Green – Rapid Flashing (loading state): Filament has been fed into the canister drive and is in the
process of loading to the head; canister cannot be removed.
Green – Steady: Filament is loaded to the head; canister cannot be removed.
Red – Flashing: Canister load/unload failure or canister memory chip read/write failure has occurred;
canister should be removed.
Red – Steady: Empty canister; canister should be removed.

TIP WIPE HEIGHT ADJUSTMENT WHEELS

The canister bay enclosure contains adjustment wheels for both the model and support tip wipes. These wheels
allow you to manually adjust tip wipe heights to ensure proper placement. After replacing a tip you must adjust
that tip's tip wipe height using the tip's corresponding adjustment wheel. See
page 164
for instructions.
Figure 3-9:
Tip Wipe Height Adjustment Wheel Locations
32
"Adjusting Tip Wipe Heights" on
Model Tip Wipe
Height Adjustment
Wheel
Support Tip Wipe
Height Adjustment
Wheel

Advertisement

Table of Contents
loading

This manual is also suitable for:

K7 seriesFortus 380mcFortus 380mc carbon fiberFortus k6 seriesFortus k7 seriesFortus 380mc carbon fiber edition