5 Facility Requirements
5.1 Electrical Power Requirements
Your printer has the following electrical requirements.
5.1.1 Power
Voltage
100–120 VAC single-phase, 50–60 Hz
200–240 VAC single-phase, 50–60 Hz
A Type C circuit breaker with the following specification is recommended
on the printer's power line, subject to the local electrical code.
Voltage
100–120 VAC
200–240 VAC
Table 4: Circuit breaker requirements
A stable and uninterrupted power supply is required. The power to the
system should be supplied directly from the main electrical panel, without
any tapped feeds on the line.
5.1.2 Grounding
The printer is grounded through a single‐phase AC plug. Make sure that
the ground connection in the wall outlet is properly grounded, in
accordance with the local electrical safety codes.
5.1.3 Main Power Connectors
The printer is shipped without a power cable. The power cable is supplied
by your local Stratasys dealer.
DOC-04002
Objet Desktop 3-D Printer Site Preparation Guide
Table 3: Printer power rating
Circuit Breaker
10 A
6 A
Current
7 A
3.5 A
13