Connecting An External Regeneration Resistor - Omron R88D-KN01L-ECT-L User Manual

Ac servomotors/servo drives g5-series with built-in ethercat communications linear motor type r88l-ec series; r88d-kn*-ect-l series
Table of Contents

Advertisement

4-5-4

Connecting an External Regeneration Resistor

This section describes how to connect an External Regeneration Resistor.
Check your Servo Drive model before connecting an External Regeneration Resistor because the
connection method varies depending on the Servo Drive.
R88D-KN01L-ECT-L/-KN02L-ECT-L/-KN01H-ECT-L/
-KN02H-ECT-L/-KN04H-ECT-L
Normally B2 and B3 are open.
If an External Regeneration Resistor is necessary, connect the External Regeneration Resistor
between B1 and B2 as shown in the diagram below.
Servo Drive
Precautions for Correct Use
Precautions for Correct Use
Connect the thermal switch output so that the main circuit power supply is shut OFF when the
contacts open.
When using multiple External Regeneration Resistors, connect each thermal switch in series.
The resistor may be damaged by burning, or cause fire if it is used without setting up a power
supply shutoff sequence using the output from the thermal switch.
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Thermal Switch Output
θ>
B1
External Regeneration
Resistor
B2
4 System Design
4 - 51
4