Omron R88D-KN01L-ECT-L User Manual page 289

Ac servomotors/servo drives g5-series with built-in ethercat communications linear motor type r88l-ec series; r88d-kn*-ect-l series
Table of Contents

Advertisement

Gain Switching Hysteresis in Position Control
3118 hex
Setting
0 to 20,000
range
Size
2 bytes (INT16)
• Set the hysteresis width above and below the judgement level set in the Gain Switching Level in
Position Control (3117 hex).
• The unit depends on the setting of the Switching Mode in Position Control (3115 hex).
• The Gain Switching Delay Time in Position Control
(3116 hex), Gain Switching Level in Position Control
(3117 hex), and Gain Switching Hysteresis in Position
Control (3118 hex) are defined as shown in the diagram
to the right.
• The settings for the Gain Switching Level in Position Control (3117 hex) and the Gain Switching
Hysteresis in Position Control (3118 hex) are enabled as absolute values.
Position Gain Switching Time
3119 hex
Setting
0 to 10,000
range
Size
2 bytes (INT16)
• Torque fluctuations or vibration will occur if the position loop gain is changed too quickly during
position control or fully-closed control. To suppress these, set a Position Gain Switching Time
(3119 hex).
• By setting the Position Gain Switching Time (3119 hex), the gain will be switched gradually when
there is a large change in the position loop gain.
• If there is a large difference between Position Loop Gain 1 (3100 hex) and Position Loop Gain 2
(3105 hex), set the Position Gain Switching Time (3119 hex).
• When the Position Loop Gain 1 increases, the gain changes in the set time.
Position Loop Gain 1 < Position Loop Gain 2
Position
Loop Gain 2
Position Loop Gain 1
Position Loop Gain 1
Precautions for Correct Use
Precautions for Correct Use
When the position loop gain is switched to a smaller value, Position Gain Switching Time
(3119 hex) is ignored and the gain is switched immediately.
In the above figure, this operation occurs when switching from Gain 2 to Gain 1.
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Unit
Access
0.1 ms
Unit
Access
Position Gain Switching Time [ms]
3119 hex
Position Loop Gain 2
9 Servo Parameter Objects
Default
33
setting
RW
PDO map
3117 hex
0
Gain 1
Gain 2
Default
33
setting
RW
PDO map
Position Loop Gain 1
csp pp hm
Data
B
attribute
Not possible
3118 hex
Gain 1
3116 hex
csp pp hm
Data
B
attribute
Not possible
9
9 - 13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents