Omron R88D-KN01L-ECT-L User Manual page 264

Ac servomotors/servo drives g5-series with built-in ethercat communications linear motor type r88l-ec series; r88d-kn*-ect-l series
Table of Contents

Advertisement

7 Applied Functions
Precautions for Correct Use
Precautions for Correct Use
• If Gain 3 is not used, set the Gain 3 Effective Time (3605 hex) to 0 and the Gain 3 Ratio
Setting (3606 hex) to 100.
• In the Gain 3 region, only the position loop gain and the speed loop gain are treated as Gain 3,
and the Gain 1 setting is applied for all other gains.
• If the Gain 2 switching condition is established in the Gain 3 region, operation switches to Gain
2.
• If Gain 2 is switching to Gain 3, the Position Gain Switching Time (3119 hex) is applied.
• There is a Gain 3 region even when Gain 2 is switched to Gain 1 due to an object change and
so forth.
7 - 38
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications