Omron R88D-KN01L-ECT-L User Manual page 607

Ac servomotors/servo drives g5-series with built-in ethercat communications linear motor type r88l-ec series; r88d-kn*-ect-l series
Table of Contents

Advertisement

Event name
External Encoder Communications Warning
Description
The external encoder had more communications errors than the specified value.
EtherCAT Master Function Module Source
Source
Error
Level
attributes
Effects
User program
EtherNet/IP NET RUN
Indicators
System
-defined
variables
Assumed cause
There is insufficient external
encoder power supply voltage.
Cause and
correction
Noise is entering on the external
encoder connector cable.
Attached
None
information
Precautions/
"A9" is displayed on the front panel of the Servo Drive.
Remarks
Event name
Data Setting Warning
Description
An object setting is out of range.
EtherCAT Master Function Module Source
Source
Error
Level
attributes
Effects
User program
EtherNet/IP NET RUN
Indicators
System
-defined
variables
Assumed cause
Cause and
An object setting is out of range.
correction
Attached
None
information
Precautions/
"B0" is displayed on the front panel of the Servo Drive.
Remarks
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
details
Observation
Recovery
Continues.
Operation
Variable
None
Provide the required external
encoder power supply voltage 5
VDC ±5% (4.75 to 5.25 V).
If the motor cable and the external
encoder cable are bundled
together, separate them. Connect
the shield to FG.
details
Observation
Recovery
Continues.
Operation
Variable
None
Correct the object settings so that
they are within the specified
ranges.
Event code
Slave
Not affected.
EtherNet/IP NET ERR
Data type
Correction
Event code
Slave
Not affected.
EtherNet/IP NET ERR
Data type
Correction
Appendices
0807 0000 hex
Detection
Continuously
timing
System
Log category
EtherNet/IP LINK/ACT
Name
Prevention
Provide the required external
encoder power supply voltage 5
VDC ±5% (4.75 to 5.25 V).
If the motor cable and the external
encoder cable are bundled
together, separate them. Connect
the shield to FG.
34E0 0000 hex
Detection
Continuously
timing
System
Log category
EtherNet/IP LINK/ACT
Name
Prevention
Correct the object settings so that
they are within the specified
ranges.
A - 161