Omron R88D-KN01L-ECT-L User Manual page 575

Ac servomotors/servo drives g5-series with built-in ethercat communications linear motor type r88l-ec series; r88d-kn*-ect-l series
Table of Contents

Advertisement

Event name
Servo Drive Overheat
Description
The temperature of the Servo Drive radiator or power elements exceeded the specified value.
EtherCAT Master Function Module Source
Source
Error
Level
attributes
Effects
User program
EtherNet/IP NET RUN
Indicators
System
-defined
variables
Assumed cause
The ambient temperature of the
Servo Drive exceeded the
specified value.
Cause and
Overload
correction
Attached
None
information
Precautions/
"15" is displayed on the Servo Drive front panel and F015 is given as the AlarmCode (4001 hex).
Remarks
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
details
Minor fault
Recovery
Continues.
Operation
Variable
None
Improve the ambient temperature
and the cooling conditions of the
Servo Drive.
Increase the capacities of the
Servo Drive and the motor. Or,
increase the setting of the
acceleration/deceleration time and
lighten the load.
Event code
Slave
Error reset
(after cycling slave
power)
Power drive circuit is OFF for relevant slave.
EtherNet/IP NET ERR
Data type
Correction
Appendices
34E1 0000 hex
Detection
Continuously
timing
System
Log category
EtherNet/IP LINK/ACT
Name
Prevention
Check the ambient temperature of
the Servo Drive and set up the
necessary cooling conditions.
Increase the setting of the
acceleration/deceleration time
and lighten the load as much as
possible.
A - 129