Omron R88D-KN01L-ECT-L User Manual page 346

Ac servomotors/servo drives g5-series with built-in ethercat communications linear motor type r88l-ec series; r88d-kn*-ect-l series
Table of Contents

Advertisement

9 Servo Parameter Objects
Motor Overload Curve Selection
3929 hex
Setting
0 to 7
range
Size
2 bytes (INT16)
• Select one of the eight motor overload characteristic curves.
For details on the motor overload curves, refer to 3-2 Overload Characteristics (Electronic Thermal
Function) on page 3-25.
Precautions for Correct Use
Precautions for Correct Use
• The overload protection function is not designed to provide protection against errors caused
by heat generated by the motor.
• Therefore, if you set the Motor Overload Curve Selection (3929 hex) value too high, the Motor
Coil Unit may burn. Check in the actual operating environment to be sure that no problem
occurs due to heat generated by the motor or other causes before using the Servo Drive.
9 - 70
Unit
Access
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Default
0
setting
RW
PDO map
A l l
Data
R
attribute
Not possible