Appendices
Event name
Interface Input Duplicate Allocation Error 1
Description
There is a duplicate setting in the input signal (IN1, IN2, IN3, and IN4) function allocations.
EtherCAT Master Function Module
Source
Error
Level
attributes
Effects
User program
EtherNet/IP NET RUN
Indicators
System
-defined
variables
Assumed cause
Cause and
There is a duplicate setting in the
correction
input signal (IN1, IN2, IN3, and
IN4) function allocations.
Attached
None
information
Precautions/
"33" is displayed on the Servo Drive front panel and F033 is given as the AlarmCode (4001 hex).
Remarks
Event name
Interface Input Duplicate Allocation Error 2
Description
There is a duplicate setting in the input signal (IN5, IN6, IN7, and IN8) function allocations.
EtherCAT Master Function Module
Source
Error
Level
attributes
Effects
User program
EtherNet/IP NET RUN
Indicators
System
-defined
variables
Assumed cause
Cause
There is a duplicate setting in the
and
input signal (IN5, IN6, IN7, and
correction
IN8) function allocations.
Attached
None
information
Precautions/
"33" is displayed on the Servo Drive front panel and F133 is given as the AlarmCode (4001 hex).
Remarks
A - 138
Source
details
Minor fault
Recovery
Continues.
Operation
–
Variable
None
Allocate the functions to the
connector pins so that each
function is allocated only once.
Source
details
Minor fault
Recovery
Continues.
Operation
–
Variable
None
Allocate the functions to the
connector pins so that each
function is allocated only once.
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Event code
Slave
Error reset
(after cycling slave
power)
Power drive circuit is OFF for relevant slave.
EtherNet/IP NET ERR
–
Data type
–
Correction
Event code
Slave
Error reset
(after cycling slave
power)
Power drive circuit is OFF for relevant slave.
EtherNet/IP NET ERR
–
Data type
–
Correction
3845 0000 hex
When
establishing
communications
after turning ON
Detection
power to the
timing
slave or when
transferring
EtherCAT
Configuration
Setup
System
Log category
EtherNet/IP LINK/ACT
–
Name
–
Prevention
Allocate the functions to the
connector pins so that each
function is allocated only once.
3846 0000 hex
When
establishing
communications
after turning ON
Detection
power to the
timing
slave or when
transferring
EtherCAT
Configuration
Setup
System
Log category
EtherNet/IP LINK/ACT
–
Name
–
Prevention
Allocate the functions to the
connector pins so that each
function is allocated only once.