4 System Design
Leakage Breaker
• Select a leakage breaker for high frequencies and surge resistance.
• When selecting leakage breakers, remember to add the leakage current from devices other than the
motor, such as devices using a switching power supply, noise filters, inverters, and so on.
To prevent malfunction due to inrush current, we recommend using a leakage breaker of 10 times the
total of all leakage current values.
• The leakage breaker is activated at 50% of the rated current. Select a leakage breaker with
approximately twice the capacity.
• For details on leakage breakers selection method, refer to the manufacturer's catalog.
• Because switching takes place inside the Servo Drives, high-frequency current leaks from the SW
elements of the Servo Drive, the armature of the motor, and the cables.
High-frequency, surge-resistant leakage breakers, because they do not detect high-frequency
current, can prevent operation with high-frequency leakage current.
When using a general leakage breaker, use 3 times the total of the leakage current given in the
following table as a reference value.
The following table shows the leakage current of each Servo Drive model.
Servo Drive model
R88D-KN01L-ECT-L
R88D-KN02L-ECT-L
R88D-KN04L-ECT-L
R88D-KN01H-ECT-L
R88D-KN02H-ECT-L
R88D-KN04H-ECT-L
R88D-KN08H-ECT-L
R88D-KN10H-ECT-L
R88D-KN15H-ECT-L
R88D-KN06F-ECT-L
R88D-KN10F-ECT-L
R88D-KN15F-ECT-L
R88D-KN20F-ECT-L
R88D-KN30F-ECT-L
Note 1 These values vary greatly depending on the installation conditions of the motor power cable and the
measurement conditions. Use them for reference only.
2 The leakage current with a power cable length of 20 m is at most approximately twice as large as that with
a power cable length of 3 m.
3 The leakage current with a single-phase 200-VAC input power supply is approximately 0.8 times as large
as that with a 3-phase input power supply.
4 - 34
Leakage current
Input power supply
(Power cable: 3 m)
Single-phase 100 V
Single-phase 100 V
Single-phase 100 V
3-phase 200 V
3-phase 200 V
3-phase 200 V
3-phase 200 V
3-phase 200 V
3-phase 200 V
3-phase 400 V
3-phase 400 V
3-phase 400 V
3-phase 400 V
3-phase 400 V
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
0.6 mA
0.6 mA
0.7 mA
1.3 mA
1.3 mA
1.4 mA
1.6 mA
1.8 mA
3.5 mA
3.0 mA
3.4 mA
4.0 mA
4.9 mA
8.6 mA

Hide quick links: