Objects Requiring Settings - Omron R88D-KN01L-ECT-L User Manual

Ac servomotors/servo drives g5-series with built-in ethercat communications linear motor type r88l-ec series; r88d-kn*-ect-l series
Table of Contents

Advertisement

11 Adjustment Functions

11-11-2 Objects Requiring Settings

Index
3004 hex
Mass Ratio
3100 hex
Position Loop Gain 1
3101 hex
Speed Loop Gain 1
3610 hex
Function Expansion Setting,
11-11-3 Operating Procedure
1
Set the Mass Ratio (3004 hex).
Set the Mass ratio as correctly as possible.
• If the Mass Ratio (3004 hex) is obtained in realtime autotuning, use the set value.
• If the mass ratio is calculated in load calculation etc., input the calculated value.
• If the mass ratio is not known, perform autotuning and set the result in the Mass Ratio
(3004 hex).
2
Adjust the Position Loop Gain 1 (3100 hex), Speed Loop Gain 1 (3101 hex), Speed Loop
Integral Time Constant 1 (3102 hex), and Force Command Filter Time Constant 1
(3104 hex) settings.
If no problem occurs in realtime autotuning, you can continue to use the settings.
3
Set the Function Expansion Setting (3610 hex).
• Set whether to enable or disable the instantaneous speed observer function in bit 0.
If you set this to 1 (enabled), the speed detection method switches to instantaneous speed
observer.
• If fluctuations in the force waveform or the operation noise increase significant enough to
cause a problem, return the setting to 0 and make sure that the mass ratio or the adjustment
objects are correct.
• If fluctuations in the force waveform or the operation noise decrease, make small adjustments
to the Mass Ratio (3004 hex) to find the setting that makes the smallest fluctuations while
monitoring the Following Error Actual Value waveform and the actual speed waveform.
• If Position Loop Gain 1 (3100 hex), Speed Loop Gain 1 (3101 hex), or Speed Loop Integral
Time Constant 1 (3102 hex) is changed, the optimal value for the Mass Ratio (3004 hex) may
change, so make small adjustments to the value of the Mass Ratio (3004 hex) again to set a
value that makes the smallest fluctuations.
11 - 36
Name
Set The Mass Ratio.
Set The Position Loop Gain 1.
Set The Speed Loop Gain 1.
Set whether to enable or disable the instantaneous
observer function.
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Description
Reference
P. 9-5