7 Applied Functions
7-3-3

Operation Example

No Position Command Input (Servo ON)
No position command is entered. The motor's allowable operating range is the range set in object 3514
hex on both the right and left. An overrun limit error will occur (Error No. 34.0) if the load enters the error
range due to vibration.
Positive Movement (Servo ON)
When a positive position command is entered, the Motor's allowable operating range increases by the
commanded amount. The resulting range will be the position command input range added with the
amount of movement set in 3514 hex on both sides.
Negative Movement (Servo ON)
When a negative position command is entered, the Linear Motor's allowable operating range further
increases.
7 - 12