Standard Models and Specifications
D Wiring
Parameter Unit
Symbol
Connector socket:
D8410-4501 (Sumitomo 3M)
Connector case:
D79004-3210 (Sumitomo 3M)
Contacts:
3690-1000 (Sumitomo 3M)
2-9

External Regeneration Resistors/Resistance Units

If the Servomotor's regenerative energy is excessive, connect an External Regenera-
tion Resistor or an External Regeneration Resistance Unit.
H R88A-RR22047S External Regeneration Resistor
R88A-RR88006 External Regeneration Resistance Unit
H Specifications
Servodrive
N/A
R88D-WT60H
R88D-WT75H/110H/150H R88A-RR1K803
R88D-WT60HF/75HF
R88D-WT110HF/150HF
2-136
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
Orange/Red (--)
Orange/Black (--)
Gray/Red (--)
Gray/Black (--)
White/Red (--)
Yellow/Black (--)
Pink/Red (--)
Cable: AWG26 × 7C UL2464
Model
R88A-RR22047S
47 Ω ± 5%
R88A-RR8806
6.25 Ω ± 10%
3.13 Ω
R88A-RR88018
18 Ω
R88A-RR1K814
14.25 Ω
Servo Driver
Symbol
Shell
Connector plug:
10114-3000VE (Sumitomo 3M)
Connector case:
10314-52A0-008 (Sumitomo 3M)
Resistance
Nominal capacity
220 W
880 W
1760 W
880 W
1760 W
Chapter 2
Regeneration
absorption
70 W
180 W
--
--
--

Advertisement

Table of Contents
loading