Omron R88D-KN01L-ECT-L User Manual page 342

Ac servomotors/servo drives g5-series with built-in ethercat communications linear motor type r88l-ec series; r88d-kn*-ect-l series
Table of Contents

Advertisement

9 Servo Parameter Objects
Magnetic Pole Detection Method
3920 hex
Setting
0 to 3
range
Size
2 bytes (INT16)
• Set the magnetic pole detection method.
Explanation of Settings
Set value
0
Not specified
1
Reserved
2
Magnetic pole position estimation method
3
Magnetic pole position restoration method
For details on the Magnetic Pole Detection Method, refer to Setting the Magnetic Pole Detection Data
on page 10-9.
Precautions for Correct Use
Precautions for Correct Use
If you set this object to 0, a Motor Setting Error (Error No. 60.0) will occur.
Magnetic Pole Position Estimation Force Command Time
3922 hex
Setting
0 to 200
range
Size
2 bytes (INT16)
• Set the force application time for a single force command during magnetic pole position estimation.
• If the number of motor movement pulses reaches the value set in the Magnetic Pole Position
Estimation Maximum Movement (3924 hex) or larger, the force command will stop even before the
force application time expires.
• This setting is enabled only when the Magnetic Pole Detection Method (3920 hex) is set to 2
(Magnetic pole position estimation).
Precautions for Correct Use
Precautions for Correct Use
• If this object is set to a small value, the motor may not show its full performance, resulting in a
poor detection accuracy or a Magnetic Pole Position Estimation Error. If the motor is subjected
to a large load or resistance, set a sufficiently long force command time.
• The magnetic pole position estimation accuracy may be improved by increasing the set value
in the Magnetic Pole Position Estimation Force Command Time (3922 hex) or Magnetic Pole
Position Estimation Force Command (3923 hex). However, if you set a large value in the
Magnetic Pole Position Estimation Force Command Time (3922 hex), an Overload Error (Error
No. 16.0) will occur depending on the Magnetic Pole Position Estimation Force Command
(3923 hex) setting.
• The actual command time will be approximately the set value plus 4 ms.
9 - 66
Unit
Access
Description
ms
Unit
Access
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Default
0
setting
RW
PDO map
Default
200
setting
RW
PDO map
A l l
Data
R
attribute
Not possible
A l l
Data
B
attribute
Not possible