Omron R88D-KN01L-ECT-L User Manual page 532

Ac servomotors/servo drives g5-series with built-in ethercat communications linear motor type r88l-ec series; r88d-kn*-ect-l series
Table of Contents

Advertisement

Appendices
Sub-
Index
Name
Index
3003 hex
00 hex
Realtime Autotuning
Machine Rigidity
Setting
3004 hex
00 hex
Mass Ratio
3013 hex
00 hex
Force Limit 1
3016 hex
00 hex
Regeneration Resistor
Selection
3017 hex
00 hex
External Regeneration
Resistor Setting
3100 hex
00 hex
Position Loop Gain 1
3101 hex
00 hex
Speed Loop Gain 1
3102 hex
00 hex
Speed Loop Integral
Time Constant 1
3103 hex
00 hex
Speed Feedback Filter
Time Constant 1
3104 hex
00 hex
Force Command Filter
Time Constant 1
3105 hex
00 hex
Position Loop Gain 2
3106 hex
00 hex
Speed Loop Gain 2
3107 hex
00 hex
Speed Loop Integral
Time Constant 2
3108 hex
00 hex
Speed Feedback Filter
Time Constant 2
3109 hex
00 hex
Force Command Filter
Time Constant 2
3110 hex
00 hex
Speed Feed-forward
Gain
3111 hex
00 hex
Speed Feed-forward
Command Filter
3112 hex
00 hex
Force Feed-forward
Gain
3113 hex
00 hex
Force Feed-forward
Command Filter
*1 The default setting is 11 for a Drive for 200 V and 1 kW or greater, or for a Drive for 400 V. It is set to 13 for other Drives.
*2 The default setting is 0 for a Drive for 100 V and 400 W, for 200 V and 750 W or greater, or for a Drive for 400 V. It is set
to 3 for other Drives.
*3 The default setting is 320 for a Drive for 200 V and 1 kW or greater, or for a Drive for 400 V. It is set to 480 for other
Drives.
*4 The default setting is 180 for a Drive for 200 V and 1 kW or greater, or for a Drive for 400 V. It is set to 270 for other
Drives.
*5 The default setting is 310 for a Drive for 200 V and 1 kW or greater, or for a Drive for 400 V. It is set to 210 for other
Drives.
*6 The default setting is 126 for a Drive for 200 V and 1 kW or greater, or for a Drive for 400 V. It is set to 84 for other Drives.
*7 The default setting is 380 for a Drive for 200 V and 1 kW or greater, or for a Drive for 400 V. It is set to 570 for other
Drives.
*8 The default setting is 180 for a Drive for 200 V and 1 kW or greater, or for a Drive for 400 V. It is set to 270 for other
Drives.
*9 The default setting is 126 for a Drive for 200 V and 1 kW or greater, or for a Drive for 400 V. It is set to 84 for other Drives.
A - 86
Default
Setting range
setting
*1
0 to 31
11/13
250
0 to 10,000
5,000
0 to 5,000
*2
0 to 3
0/3
0
0 to 4
*3
0 to 30,000
320/480
*4
1 to 32,767
180/270
*5
1 to 10,000
210/310
0
0 to 5
*6
0 to 2,500
84/126
*7
0 to 30,000
380/570
*8
1 to 32,767
180/270
10,000
1 to 10,000
0
0 to 5
*9
0 to 2,500
84/126
300
0 to 1,000
50
0 to 6,400
0
0 to 1,000
0
0 to 6,400
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Data
Unit
Size
attribute
2 bytes
B
(INT16)
%
2 bytes
B
(INT16)
0.1%
2 bytes
B
(INT16)
2 bytes
C
(INT16)
2 bytes
C
(INT16)
0.1/s
2 bytes
B
(INT16)
0.1 Hz
2 bytes
B
(INT16)
0.1 ms
2 bytes
B
(INT16)
2 bytes
B
(INT16)
0.01 ms
2 bytes
B
(INT16)
0.1 Hz
2 bytes
B
(INT16)
0.1 Hz
2 bytes
B
(INT16)
0.1 ms
2 bytes
B
(INT16)
2 bytes
B
(INT16)
0.01 ms
2 bytes
B
(INT16)
0.1%
2 bytes
B
(INT16)
0.01 ms
2 bytes
B
(INT16)
0.1%
2 bytes
B
(INT16)
0.01 ms
2 bytes
B
(INT16)
PDO
Corresponding
map
Pn number
Not
Pn003
possible
Not
Pn004
possible
Not
Pn753
possible
Not
Pn016
possible
Not
Pn017
possible
Not
Pn100
possible
Not
Pn101
possible
Not
Pn102
possible
Not
Pn103
possible
Not
Pn104
possible
Not
Pn105
possible
Not
Pn106
possible
Not
Pn107
possible
Not
Pn108
possible
Not
Pn109
possible
Not
Pn110
possible
Not
Pn111
possible
Not
Pn112
possible
Not
Pn113
possible

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents