Omron R88D-KN01L-ECT-L User Manual page 201

Ac servomotors/servo drives g5-series with built-in ethercat communications linear motor type r88l-ec series; r88d-kn*-ect-l series
Table of Contents

Advertisement

Available PDO Mapping Combinations
Receive PDO mapping (RxPDO)
One of the mappings in 1701 to 1705 hex and another
in 1600 hex
*1 A maximum of 10 objects in total can be mapped to the Receive PDO mapping.
*2 A maximum of 11 objects in total can be mapped to the Transmit PDO mapping.
Precautions for Correct Use
Precautions for Correct Use
• The communications cycle you can set varies depending on the total size of mapped objects.
For details, refer to A-1-3 Communications Cycles and Corresponding Modes of Operation on
page A-5.
• If the size of the mapped objects exceeds the maximum total size, a Function Setting Error
(Error No. 93.4) will occur.
• If the number of the mapped objects exceeds the maximum allowed number, a Function
Setting Error (Error No. 93.4) will occur.
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
5 EtherCAT Communications
*1
Transmit PDO mapping (TxPDO)
• One of the mappings in 1B01 to 1B04 hex and
another in 1A00 hex
• One of the mappings in 1B01 to 1B04 hex and
another in 1BFF hex
• One mapping in 1A00 hex and another in 1BFF hex
*2
5
5 - 11