Appendices
Event name
Position Data Initialized
Description
A Config operation was performed during EtherCAT communications.
EtherCAT Master Function Module Source
Source
Error
Level
attributes
Effects
User program
EtherNet/IP NET RUN
Indicators
System
-defined
variables
Assumed cause
Cause and
A Config operation was performed
correction
during EtherCAT communications.
Attached
None
information
Precautions/
"27" is displayed on the Servo Drive front panel and F727 is given as the AlarmCode (4001 hex).
Remarks
Event name
Fan Warning
Description
The fan stop state continued for 1 second.
EtherCAT Master Function Module Source
Source
Error
Level
attributes
Effects
User program
EtherNet/IP NET RUN
Indicators
System
-defined
variables
Assumed cause
There is foreign matter in the fan.
Cause and
correction
The Servo Drive failed.
Attached
None
information
Precautions/
"A3" is displayed on the front panel of the Servo Drive.
Remarks
A - 158
details
Minor fault
Recovery
Continues.
Operation
–
Variable
None
This operation is performed for
safety and is not an error.
details
Observation
Recovery
Continues.
Operation
–
Variable
None
If there is foreign matter in the fan,
remove it.
If the above cause is not the cause
of the problem, replace the Servo
Drive.
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Event code
Slave
Error reset
(after resetting slave
errors)
Power drive circuit is OFF for relevant slave.
EtherNet/IP NET ERR
–
Data type
–
Correction
Event code
Slave
–
Not affected.
EtherNet/IP NET ERR
–
Data type
–
Correction
9802 0000 hex
Detection
Continuously
timing
System
Log category
EtherNet/IP LINK/ACT
–
Name
–
Prevention
(A preventative measure is not
required because this is a safety
measure.)
0802 0000 hex
Detection
Continuously
timing
System
Log category
EtherNet/IP LINK/ACT
–
Name
–
Prevention
Do not use the fan in an area
surrounded by excessive foreign
matter. Also, do not allow foreign
objects to enter.
None