Immediate Stop Operation At Errors - Omron R88D-KN01L-ECT-L User Manual

Ac servomotors/servo drives g5-series with built-in ethercat communications linear motor type r88l-ec series; r88d-kn*-ect-l series
Table of Contents

Advertisement

Error No.
Main
Sub
93 hex
0 hex
3 hex
4 hex
99 hex
0 hex
Other numbers
*1 Deceleration method: When the Fault reaction option code (605E hex) is set to -4 to -7, the stop distance
differs depending on the error number. However, any error that will occur during magnetic pole position
estimation causes operation B.
For details, refer to Fault reaction option code on page A-92.
*2 This error cannot be reset for 10 seconds after it occurs.
*3 Communications Errors (Error No. 83.1 to 83.5) and the Communications Setting Error (Error No. 90.0) cannot
be reset until the cause of the error is removed by performing an operation from the master.
When resetting an error via a USB connection, remove the cause of the error beforehand.
Note 1 If an error that cannot be reset occurs, remove the error factor and turn OFF the control power to reset the
error.
2 If a resettable error occurs, reset the error via EtherCAT communications or on the CX-Drive.
F
3 If "hh," "
power immediately if one of these error numbers is displayed.

12-3-2 Immediate Stop Operation at Errors

The immediate stop function controls the motor and stop it if an error that causes an immediate stop
(Deceleration method: operation A) occurs.
For the applicable errors, refer to 12-3-1 Error List on page 12-9. This function applies to those errors
that are indicated as "A" in the Deceleration method column.
Related Objects
Index
605E hex
Fault reaction option code
3511 hex
Immediate Stop Force
3614 hex
Error Detection Allowable Time
Setting
3615 hex
Overspeed Detection Level
Setting at Immediate Stop
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Error detection function
Object Setting Error 1
External Encoder Connection Error
Function Setting Error
Other errors
F
," or "HH" is displayed as the error number, the internal MPU has malfunctioned. Turn OFF the
Name
12 Troubleshooting and Maintenance
History
Description
Set the state during deceleration and after
stopping for when an error occurs.
Set the force limit for immediate stops.
Set the allowable time until stopping if an
immediate stop is executed when an error is
detected.
If the motor speed exceeds the set value during
an immediate stop resulting from an error, an
Overspeed 2 Error (Error No. 26.1) will occur.
Attribute
Deceleration
Can be
*1
reset
method
B
B
B
B
Reference
P. A-61
P. 9-43
P. 9-49
P. 9-50
12 - 11
12