Communication Address For Plc Devices - Delta C2000 series User Manual

Classical field oriented. control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement

Special D
The mapping address 3(L) for slave No. n
D2096+100*n
receiving station 4
The mapping address 3(H) for slave No.n
D2097+100*n
receiving station 4
The mapping address 4(L) for slave No. n
D2098+100*n
receiving station 4
The mapping address 4(H) for slave No.n
D2099+100*n
receiving station 4

16.4.4 Communication Address for PLC Devices

Device
X
Y
T
M
M
C
D
D
D
Function Code
Function Code
01
02
03
05
06
0F
10
Only when PLC is at Stop status, PLC data can be read/write via communication device. When PLC
is at Run status, the communication address should be the mapping address, e.g. for Pr.04-00 it
maps to 0400H.
NOTE
When PLC function is activated, C2000 can Read/Write the PLC and drive's parameter by different addresses (pre-defined
station number for the AC motor drive is 1, for PLC station number is 2)
Function
Range
00~17 (Octal)
00~17 (Octal)
00~159
000~799
1000~1079
0~79
00~399
1000~1099
2000~2799
Description
Read coil status
Read input status
Read one data
Force changing one coil status
Write in one data
Force changing multiple coil
Write in multiple data
Chapter 16 PLC Function |C2000 Series
PDO
Map
NO
NO
NO
NO
Type
bit
bit
bit/word
bit
bit
bit/word
word
word
word
status
16-35
Pre-defined
Save
Setting
YES
0
YES
0
YES
0
YES
0
Address (Hex)
0400~040F
0500~050F
0600~069F
0800~0B1F
0BE8~0C37
0E00~0E47
1000~118F
13E8~144B
17D0~1AEF
Supported Devices
Y, M, T, C
X,Y,M,T,C
T,C,D
Y,M,T,C
T,C,D
Y,M,T,C
T,C,D
R/W
RW
RW
RW
RW