Chapter 14 Fault Codes and Descriptions |C2000 Series
Fault Name
Fault
EoL2
Thermal relay 2
Fault
ot1
Over torque 1
Fault
ot2
Over torque 2
Fault
uC
Under torque
Fault
LMIT
Limit Err or
Fault
cF1
EEPROM write err
Fault
cF2
EEPROM read err
Fault
cd1
Ias sensor err
Fault
cd2
Ibs sensor err
Fault
cd3
Ics sensor err
Fault Descriptions
Electronics thermal relay
2 protection
These two fault codes
will be displayed when
output current exceeds
the over-torque detection
level (Pr.06-07 or
Pr.06-10) and exceeds
over-torque detection
(Pr.06-08 or Pr.06-11)
and it is set to 2 or 4 in
Pr.06-06 or Pr.06-09.
Low current detection
Limit error
Internal EEPROM can
not be programmed.
Internal EEPROM can
not be read.
U-phase error
V-phase error
W-phase error
Corrective Actions
1. Check the setting of electronics thermal relay
(Pr.06-28)
2. Take the next higher power AC motor drive
model
1. Check whether the motor is overloaded.
2. Check whether motor rated current setting
(Pr.05-01) is suitable
3. Take the next higher power AC motor drive
model.
Check Pr.06-71, Pr.06-72, Pr.06-73.
1. Press "RESET" key to the factory setting
2. Return to the factory.
1. Press "RESET" key to the factory setting
2. Return to the factory.
Reboots the power. If fault code is still displayed on the
keypad please return to the factory
Reboots the power. If fault code is still displayed on the
keypad please return to the factory
Reboots the power. If fault code is still displayed on the
keypad please return to the factory
14-4