Delta C2000 series User Manual page 127

Classical field oriented. control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement

Chapter 8 Optional Cards |C2000 Series
EMC-PG01R
Terminal Descriptions
Set by Pr.10-00~10-02
Terminals
R1- R2
PG1
S1,S2, S3, S4,
A2, /A2,
PG2
B2, /B2
AO, /AO,
BO, /BO,
PG OUT
ZO, /ZO
Note 1: Open Collector application, input current 5~15mA to each set then each set needs one pull-up resistor.
5V
12V
24V
PG2 Wiring Diagram
Resolver Output Power
7Vrms, 10kHz
Resolver Input Signal
3.5±0.175Vrms, 10kHz
Pulse Input signal
Open Collector Input Voltage: +5~+24V (Note1)
It can be 1-phase or 2-phase input.
Max. output frequency: 300kP/sec.
PG Card Output signals. It has division frequency function: 1~255
times
Max. output voltage for Line driver: 5VDC
Max. output current: 50mA
,
Max. output frequency: 300kP/sec
SG,
SG is the GND of PG card. It is also the GND of position machine or PLC to
make the ouput signal to be the common pivot point.
Recommanded pull-up resistor: above100~220Ω, 1/2W
Recommanded pull-up resistor: above 510~1.35kΩ, 1/2W
Recommanded pull-up resistor, above1.8k~3.3kΩ, 1/2W
4.7k Ω
Descriptions
(Line Driver or Open Collector)
Ext Pull
high RES
AB2
AB2
8-12
Ext Power
(5-24V)
Ext Ground

Hide quick links: