Chapter 9 Specifications |C2000 Series
EMI Filter
EMC-COP01
NOTE
For FRAME A, B and C, Model VFDXXXC43A the enclosure type is IP20/NEMA1/UL TYPE1.
For FRAME D and above, if the last character of the model is A then the enclosure type is IP20 but the wiring terminal is
IP00; if the last character of the model is E, the enclosure type is IP20/NEMA1/UL TYPE1.
General Specifications
Control Method
Starting Torque
V/F Curve
Speed Response
Ability
Torque Limit
Torque Accuracy
Max. Output
Frequency (Hz)
Frequency Output
Accuracy
Output Frequency
Resolution
Overload Tolerance
Frequency Setting
Signal
Accel./decel. Time
Main control function
Fan Control
Motor Protection
Over-current
Protection
Over-voltage
Protection
Over-temperature
Protection
Stall Prevention
Restart After
Instantaneous Power
Failure
Grounding Leakage
Current Protection
Certifications
VFDXXXC43A/43E Frame D and above: EMI Filter is optional
VFDXXC43A (optional); VFDXXXC43E (built-in)
1: V/F, 2: SVC, 3: VF+PG, 4: FOC+PG, 5: TQC+PG,
Reach up to 150% or above at 0.5Hz.
Under FOC+PG mode, starting torque can reach 150% at 0Hz.
4 point adjustable V/F curve and square curve
5Hz (vector control can reach up to 40Hz)
Max. 200% torque current
±5%
Light duty and normal duty: 0.01~600.00Hz; Heavy duty: 0.00 ~ 300.00 Hz
Digital command:±0.01%, -10 ~+40
Digital command:0.01Hz, Analog command: 0.03 X max. output frequency/60 Hz
(±11 bit)
Light duty: rated output current is 110 % for 60 seconds
Normal duty: rated output current is 120% for 60 seconds
Heavy duty: rated output current is 150% for 60 seconds
+10V~-10, 0~+10V, 4~20mA, 0~20mA, Pulse input
0.00~600.00/0.0~6000.0 seconds
Torque control, Droop control, Speed/torque control switching, Feed forward control,
Zero-servo control, Momentary power loss ride thru, Speed search, Over-torque
detection, Torque limit, 17-step speed (max), Accel/decel time switch, S-curve
accel/decel, 3-wire sequence, Auto-Tuning (rotational, stationary), Dwell, Cooling fan
on/off switch, Slip compensation, Torque compensation, JOG
upper/lower limit settings, DC injection braking at start/stop, High slip braking, PID
control (with sleep function),Energy saving control, MODOBUS communication
(RS-485 RJ45, max. 115.2 kbps), Fault restart, Parameter copy
230V model
VFD150C23A(include) and series above: PMW control; VFD150C23A and series
below: on/off switch control
460V model
VFD150C23A(include) and series above: PMW control; VFD150C23A and series
below: on/off switch control
Electronic thermal relay protection
For drive model 230V and 440V
Over-current protection for 220% rated current
current clamp 『 Normal duty: 170~175% 』 ; 『 Heavy duty: 180~185% 』
230: drive will stop when DC-BUS voltage exceeds 410V
460: drive will stop when DC-BUS voltage exceeds 820V
Built-in temperature sensor
Stall prevention during acceleration, deceleration and running independently
Parameter setting up to 20 seconds
Leakage current is higher than 50% of rated current of the AC motor drive
,
, GB/T12668-2,
VFDXXXC43A: No EMI Filter;
VFDXXXC43E: Built-in EMI Filter
℃, Analog command: ±0.1%, 25±10℃
(certification in progress)
9-4
frequency,
Frequency