8. When Y=2, X=5
Z pulse
Homing by Frequency 1
Settings 0.00~600.00Hz
Homing by Frequency 2
Settings 0.00~600.00Hz
Control by Multi-funcion Input Terminal Pr. 02-01~02-08 (44~47).
44: Reverse direction homing
45: Forward direction homing
46: Homing (ORG)
47: Homing function enable
If the drive is not control by CAN or PLC, set Pr.00-10 =1 (Contorl mode = P2P position control)
and set exterminal output terminal to 47 (homing function enable) for homing.
When Pr.00-10 is set to 3, after homing is complete, user must set control mode setting Pr.00-10
to 1 in order to perform P2P position control.
~
Reserved
Display Filter Time (Current)
Settings: 0.001~65.535 sec
Set this parameter to minimize the current fluctuation displayed by digital keypad.
Display Filter Time (Keypad)
Settings: 0.001~65.535 sec
Set this parameter to minimize the display value fluctuation displayed by digital keypad.
Software Version (date)
Settings: Read only
This parameter displays the drive's software version by date.
Chapter 12 Description of Parameter Settings|C2000 Series
Spe ed
12-19
Position
Factory Setting: 8.00
Factory Setting: 2.00
Factory Settings: 0.100
Factory Settings: 0.100
Factory Settings: ####