M
M1023 Divisor is 0
M1024
Reserved
M1025
RUN(ON) / STOP(OFF) the AC motor drive
M1026
The operation direction of the AC motor drive (FWD: OFF, REV: ON)
M1027 AC motor drive reset
M1028 Reserved
M1029 Reserved
M1030 Reserved
M1031 Reserved
M1032 Reserved
M1033 Reserved
M1034 Enable CANopen real time control
M1035
~
Reserved
M1039
M1040 Power On
M1041 Reserved
M1042 Quick stop
M1043 Reserved
M1044 Halt
M1045
~
Reserved
M1047
M1048 New position
M1049~
Reserved
M1051
M1052 Freuqency Lock
M1053
~
Reserved
M1054
M1055 Home
M1056 Power on ready
M1057 Reserved
M1058 On quick stopping
M1059 CANopen master setting complete
M1060 Initializing CANopen slave
M1061 Initialize CANopen slave failed
M1062 Reserved
M1063 Target torque attained
M1064 Target position attained
M1065 Set pos ack
M1066 Read/ Write CANopen data complete
M1067 Read/ Write CANopen data suceed
Chapter 16 PLC Function |C2000 Series
Function
16-24
Read(R)/
Write(W)
Read only
-
Read/Write
Read/Write
Read/Write
Read/Write
-
Read/Write
-
Read/Write
-
Read/Write
-
Read/Write
Read/Write
-
Read/Write
Read only
-
Read only
Read only
Read only
Read only
-
Read only
Read only
Read only
Read only
Read only