Up/Down Key Mode; Constant Speed. The Accel. /Decel. Speed Of The Up/Down Key - Delta C2000 series User Manual

Classical field oriented. control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement

Settings
Functions
Mechanical gear ratio
48
switch
49
Drive enable
50
Master dEb action input
Selection for PLC mode
51
bit0
Selection for PLC mode
52
bit1
Enable CANopen quick
53
stop
54~55 Reserved
56
LOCAL/REMOTE Selection
57~70 Reserved

UP/DOWN Key Mode

Settings 0: Up/down by the accel/decel time

Constant speed. The Accel. /Decel. Speed of the UP/DOWN Key

Settings 0.01~1.00Hz/ms
These settings are used when multi-function input terminals are set to 19/20. Refer to Pr.02-09 and
02-10 for the frequency up/down command.
Pr.02-09 set to 0: it will increase/decrease frequency command (F) by the external terminal
UP/DOWN key as shown in the following diagram. In this mode, it also can be controlled by
UP/DOWN key on the digital keypad.
When this contact is ON, the mechanical gear ratio switch will be
the second group A2/B2 (refer to Pr.10-08 and Pr.10-09).
When drive=enable, RUN command is valid.
When drive= disable, RUN command is invalid.
When drive is in operation, motor coast to stop.
Input the message setting in this parameter when dEb occurs to
Master. This will ensure dEb also occurs to Slave, then Master and
Slave will stop simultaneously.
PLC status
Disable PLC function (PLC 0)
Trigger PLC to operation (PLC 1)
Trigger PLC to stop (PLC 2)
No function
When this function is enabled under CANopen control, it will
change to quick stop. Refer to Chapter 15 for more details.
Use Pr.00-29 to select for LOCAL/REMOTE mode(refer to
Pr.00-29)
When Pr.00-29 is not set to 0, on the digital keypad KPC-CC01 it
will display LOC/REM status. (It will display on the KPC-CC01 if the
firmware version is above version 1.021).
1: Up/down constant speed (Pr.02-10)
Chapter 12 Description of Parameter Settings|C2000 Series
Descriptions
Bit 0
REM
0
LOC
1
12-39
Bit 1
Bit 0
0
0
0
1
1
0
1
1
Factory Setting: 0
Factory Setting: 0.01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents