When switching the page from PLC to PLC2, it will stop PLC. Again the motion of PLC
2.
(Execute/Stop) is controlled by WPL editor.
The control of external terminals follows the same method.
3.
NOTE
When input/output terminals (FWD REV MI1~MI8 MI10~15, Relay1, Relay2 RY10~RY15, MO1~MO2 MO10~MO11,)
are used in PLC program, they cannot be used in other places. Fro example, when PLC program (PLC1 or PLC2) is
activated, such as when it controls Y0, the corresponding output terminals Relay (RA/RB/RC) will be used. At this
moment, Pr.03.00 setting will be invalid since the terminal has been used by PLC. Refer to Pr.02-52, 02-53, 03-30 to
check which DI DO AO are occupied by PLC.

16.2.2 I/O Device Reference Table

Input device
:
Device X0
X1
X2
FWD REV MI1
1
2
3
1: I/O extension card
2: I/O extension card EMC-D611A (D1022=4)
3: I/O extension card EMC-D42A (D1022=5)
Output device
:
Device Y0
Y1
Y2
RY
RY2
1
1
2
3
1: I/O extension card
2: I/O extension card EMC-D42A (D1022=5)
3: I/O extension card EMC-R6AA (D1022=6)
X3
X4
X5
X6
MI2
MI3
MI4
MI5
Y3
Y4
Y5
Y6
MO1 MO2
MO10 MO11
RY10 RY11 RY12 RY13 RY14 RY15
16-6
Chapter 16 PLC Function |C2000 Series
X7
X10
X11
X12
MI6
MI7
MI8
MI10 MI11 MI12 MI13 MI14 MI15
MI10 MI11 MI12 MI13
Y7
Y10
Y11
Y12
X13
X14
X15
X16
Y13 Y14 Y15 Y16 Y17
X17