Selectionfor Over-voltage Stall Prevention

Settings 0: Traditional over-voltage stall prevention
1: Smart over-voltage prevention
When Pr.06-02 is set to 1, the drive will maintain DCbus voltage when decelerating and prevent
OV.
0

Over-current Stall Prevention during Acceleration

Settings Normal duty: 0~160% (100%: drive's rated current)
Heavy duty: 0~180% (100%: drive's rated current)
If the motor load is too large or drive acceleration time is too short, the AC drive output current may
increase abruptly during acceleration and it may cause motor damage or trigger protection
functions (OL or OC). This parameter is used to prevent this situation.
Chapter 12 Description of Parameter Settings|C2000 Series
Deceleration c har acteristic
when Ov er-Voltag e Stall
Pr ev entio n enabled
pre vious deceleration time
requir ed time for d ecelerating to 0Hz when over- voltage
stall preven tion is enab led.
60Hz
Output Frequency
370Vdc
230V Series
12-94
F requenc y Held
Factory Setting: 0
DCBUS Voltage
310Vdc
Time
Factory Setting: 120
Factory Setting: 150
Time
Time