Group 9 Communication Parameters - Delta VFD-VL Series User Manual

Elevator drive
Table of Contents

Advertisement

Call 1(800)985-6929 for Sales
VFD-VL
Chapter 4 Parameters|

4.1.10 Group 9 Communication Parameters

Pr.
Explanation
Communication Address
09-00
Transmission Speed
09-01
Transmission Fault
09-02
Treatment
Time-out Detection
09-03
Communication Protocol
09-04
09-05 Response Delay Time
Call 1(800)985-6929 for Sales
deltaacdrives.com
Settings
1~254
4.8~115.2Kbps
0: Warn and keep operation
1: Warn and ramp to stop
2: Reserved
3: No action and no display
0.0~100.0 sec
0: 7N1 (ASCII)
1: 7N2 (ASCII)
2: 7E1 (ASCII)
3: 7O1 (ASCII)
4: 7E2 (ASCII)
5: 7O2 (ASCII)
6: 8N1 (ASCII)
7: 8N2 (ASCII)
8: 8E1 (ASCII)
9: 8O1 (ASCII)
10: 8E2 (ASCII)
11: 8O2 (ASCII)
12: 8N1 (RTU)
13: 8N2 (RTU)
14: 8E1 (RTU)
15: 8O1 (RTU)
16: 8E2 (RTU)
17: 8O2 (RTU)
0.0~200.0ms
4-16
deltaacdrives.com
sales@deltaacdrives.com
Factory
Setting
1
9.6
3
0.0
13
2.0
sales@deltaacdrives.com
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○