Disconnecting Cmc-Mod01 From Vfd-C2000; Basic Registers - Delta C2000 series User Manual

Classical field oriented. control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement

Chapter 8 Optional Cards |C2000 Series
Decoding method for
P09-30
communication
IP setting
P09-75
P09-76
IP address -1
IP address -2
P09-77
P09-78
IP address -3
IP address -4
P09-79
P09-80
Netmask -1
Netmask -2
P09-81
P09-82
Netmask -3
Netmask -4
P09-83
Default gateway -1
P09-84
Default gateway -2
P09-85
Default gateway -3
P09-86
P09-87
Default gateway -4
Disconnecting CMC- MOD01 from VFD-C2000
1.
Switch off the power supply of VFD-C2000.
2.
Remove the two screws (shown in Figure 6).
3.
Twist opens the card clip and inserts the slot type screwdriver to the hollow to prize the PCB off
the card clip (shown in Figure 7).
4.
Twist opens the other card clip to remove the PCB (shown in Figure 8).

Basic Registers

BR#
R/W
Model name
#0
R
Firmware
#1
R
version
Release date of
#2
R
the version
#11
R/W
Modbus Timeout Pre-defined setting: 500 (ms)
#13
R/W
Keep Alive Time Pre-defined setting: 30 (s)
[Figure 6]
[Figure 8]
Content
Set up by the system; read only. The model code of
CMC-MOD01=H'0203
Displaying the current firmware version in hex, e.g. H'0100 indicates the
firmware version V1.00.
Displaying the data in decimal form. 10,000s digit and 1,000s digit are for
"month"; 100s digit and 10s digit are for "day".
For 1 digit: 0 = morning; 1 = afternoon.
Decoding method for Delta AC motor
0
drive
0
Static IP(0) / Dynamic distribution IP(1)
192
IP address 192.168.1.5
168
IP address 192.168.1.5
1
IP address 192.168.1.5
5
IP address 192.168.1.5
255
Netmask 255.255.255.0
255
Netmask 255.255.255.0
255
Netmask 255.255.255.0
0
Netmask 255.255.255.0
192
Default gateway 192.168.1.1
168
Default gateway 192.168.1.1
1
Default gateway 192.168.1.1
1
Default gateway 192.168.1.1
Explanation
8-16
[Figure 7]