Delta C2000 series User Manual page 487

Classical field oriented. control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement

API
ZRST
40
P
Bit Devices
X
Y
M
K
* *
D
1
* *
D
2
Operands:
No of D
operand. ≦No. of D
1
D
and D
must select same device type
1
2
Please refer to the specification of each model series
for applicable range of the device.
: Start device of the range to be reset
D
E xplanation
1
When D
1
1. When X0 = On, auxiliary relays M300 ~ M399 will be reset to Off.
Example
2. When X1 = On, 16 counters C0 ~ C127 will all be reset (writing in 0; contact
and coil being reset to Off).
3. When X10 = On, timers T0 ~ T127 will all be reset (writing in 0; contact and coil
being reset to Off).
4. When X3 = On, data registers D0 ~ D100 will be reset to 0.
Remarks
1.
Devices, e.g. bit devices Y, M, S and Word Devices T, C, D, can use RST
instruction.
2.
API 16 FMOV instruction is also to send K0 to Word Devices T, C, D or bit
registers KnY, KnM, KnS for reset.
D1
D2
Word Devices
H KnX KnY KnM T
operand
2
> D
, only operands designated by D
2
X0
X1
X10
X3
X0
Chapter 16 PLC Function |C2000 Series
Zero Reset
16-bit command (5 STEPS)
C
D
ZRST
32-bit command
Flag signal: none
: End device of the range to be reset
D
2
will be reset.
2
ZRST
M300
ZRST
C0
ZRST
T0
ZRST
D0
RST
M0
RST
T0
RST
Y0
FMOV
K0
16-64
ZRSTP
M399
C127
T127
D100
D10
K5