Environment for Operation, Storage and Transportation

DO NOT expose the AC motor drive in the bad environment, such as dust, direct sunlight, corrosive/inflammable
gasses, humidity, liquid and vibration environment. The salt in the air must be less than 0.01mg/cm
Installation
location
Surrounding
Temperature
Rated
Humidity
Air Pressure
Environment
Pollution
Level
Altitude
Package
Storage
Drop
Transportation
1.0mm, peak to peak value range from 2Hz to 13.2 Hz; 0.7G~1.0G range from 13.2Hz to 55Hz;
Vibration
1.0G range from 55Hz to 512 Hz. Comply with IEC 60068-2-6
Impact
IEC/EN 60068-2-27
Max. allowed offset angle ±10
Operation
Position
installation position)
IEC60364-1/IEC60664-1 Pollution degree 2, Indoor use only
o
Storage
-25
C ~ +70
o
Transportation -25
C ~ +70
Non-condensation, non-frozen
Operation
Max. 90%
Storage/
Max. 95%
Transportation
No condense water
Operation/
86 to 106 kPa
Storage
Transportation 70 to 106 kPa
IEC721-3-3
Operation
Class 3C2; Class 3S2
Storage
Class 2C2; Class 2S2
Transportation Class 1C2; Class 1S2
No concentrate
If AC motor drive is installed at altitude 0~1000m, follow normal
operation restriction. If it is install at altitude 1000~3000m, decrease
2% of rated current or lower 0.5℃ of temeperature for every 100m
Operation
increase in altitude. Maximum altitude for Corner Grounded is
2000m.
ISTA procedure 1A(according to weight) IEC60068-2-31
o
(under normal
Chapter 9 Specifications |C2000 Series
o
C
o
C
10
10
9-5
2
every year.