Delta C2000 series User Manual page 478

Classical field oriented. control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement

API
BMOV
15
P
Bit Devices
X
Y
M
K
S
D
n
Operand:
Range of n =1~512
1.
S: Start of source devices D: Start of destination devices n: Number of data to
E xplanation
be moved
2.
The contents in n registers starting from the device designated by S will be
moved to n registers starting from the device designated by D. If n exceeds the
actual number of available source devices, only the devices that fall within the
valid range will be used.
When X10 = On, the contents in registers D0 ~ D3 will be moved to the 4 registers D20
Example
~ D23.
1
Assume the bit devices KnX, KnY, KnM and KnS are designated for moving, the
Example
number of digits of S and D has to be the same, i.e. their n has to be the same.
M1000
2
n
S
D
Word Devices
H KnX KnY KnM T
X10
D0
Chapter 16 PLC Function |C2000 Series
Block Move
16-bit command (7 STEPS)
C
D
BMOV
32-bit command
Flag signal: None
D0
D20
K4
D1
D2
D3
M0
D20
K4
M1
M2
M3
M4
M5
M6
M7
M8
M9
M10
M11
16-55
BMOVP
D20
D21
n=4
D22
D23
n=3
Y10
Y11
Y12
Y13