Reserved
Multi-function output terminal: Function 42: Brake Current Checking Point
Settings 0~150%
Multi-function output terminal: Function 42: Brake Frequency Checking Point
Settings 0.00~655.35Hz
Pr02-32, Pr02-33, Pr02-34, Pr02-57 and Pr02-58 can be applied on setting up cranes. (Choose
crane action #42 to set up multi-functional output Pr02-13, Pr02-14, Pr02-16, and Pr02-17)
When output current of a drive is higher than the the setting of Pr02-33 Pivot Point of the Current
(>=02-33) and when output frequency is higher than the the setting of Pr02-34 Pivot Point of the
Frequency (>= 02-34), choose #42 to set up Multi-functional output Pr02-13, Pr02-14, Pr02-16
and Pr002-17 after the delay time set at Pr402-32.
When the Pivot Point of the Current 's setting 02-57≠0 and when the output current of the drive is
lower than the setting of Pr02-57 (<02-57), or when the output frequency is lower than the setting
of Pr02-58 (<02-58), the disable the setting #42 of the multi-functional output Pr02-13, Pr02-14,
Pr02-16, Pr02-17
When Pr02-57 = 0, the output current is lower than setting of Pr02-33 Pivot Point of the
Current(<02-33) or when output frequency is lower than the setting of Pr02-58(<02-58), disable
the setting of #42 of the multi-functional output Pr02-13, Pr02-14, Pr02-16, Pr02-17.
Chapter 12 Description of Parameter Settings|C2000 Series
12-54
Factory setting: 0
Factory setting:0.00