Communication Parameters for VFD-C2000 Connected to Ethernet
When VFD-C2000 is connected to Ethernet network, please set up the communication parameters
for it according to the table below. The Ethernet master is only able to read/write the frequency word
and control word of VFD-C2000 after the communication parameters are set.
Parameter
(Dec)
Source of frequency
P00-20
command setting
Source of operation
P00-21
command setting
Decoding method for
P09-30
communication
P09-75
IP setting
P09-76
IP address -1
P09-77
IP address -2
P09-78
IP address -3
P09-79
IP address -4
P09-80
Netmask -1
P09-81
Netmask -2
P09-82
Netmask -3
P09-83
Netmask -4
P09-84
Default gateway -1
P09-85
Default gateway -2
P09-86
Default gateway -3
P09-87
Default gateway -4
[Figure 4]
Function
Set value (Dec)
8-25
Chapter 8 Optional Cards |C2000 Series
The frequency command is controlled by
8
communication card.
The operation command is controlled by
5
communication card.
The decoding method for Delta AC motor
0
drive
0
Static IP(0) / Dynamic distribution IP(1)
192
IP address 192.168.1.5
168
IP address 192.168.1.5
1
IP address 192.168.1.5
5
IP address 192.168.1.5
255
Netmask 255.255.255.0
255
Netmask 255.255.255.0
255
Netmask 255.255.255.0
0
Netmask 255.255.255.0
192
Default gateway 192.168.1.1
168
Default gateway 192.168.1.1
1
Default gateway 192.168.1.1
1
Default gateway 192.168.1.1