Mnemonic
Output coil
OUT
X0~X17
Operand
-
Output the logic calculation result before the OUT command to specific device.
Motion of coil contact:
Operation
result
FALSE
TRUE
Ladder diagram:
Example
X0
Mnemonic
Latch (ON)
SET
X0~X17
Operand
-
When the SET command is driven, its specific device is set to be "ON," which will
keep "ON" whether the SET command is still driven. You can use the RST command
to set the device to "OFF".
Ladder diagram:
X0
Example
Mnemonic
Clear the contacts or the registers
RST
X0~X17
Operand
-
When the RST command is driven, motion of its specific device is as follows:
Device
Y, M
T, C
D
When the RST command is not driven, motion of its specific device is unchanged.
Y0~Y17
M0~M799
OUT command
Coil
A contact
(normally open)
Off
Non-continuity
On
Continuity
X1
Y1
Y0~Y17
M0~M799
Y0
Y1
SET
Y0~Y17
M0~M799
Coil and contact will be set to "OFF".
Present values of the timer or counter will be set to 0, and the coil
and contact will be set to "OFF."
The content value will be set to 0.
16-41
Chapter 16 PLC Function |C2000 Series
Function
T0~159
-
Contact
B contact
(normally
closed)
Continuity
Non-continuity
Command code: Operation:
LD
X0
AND
X1
OUT
Y1
Function
T0~159
-
Command code: Operation:
LD
X0
AN
Y0
SET
Y1
Function
T0~159
Status
C0~C79
D0~D399
-
-
Load contact B of X0
Connect to contact A of
X1 in series
Drive Y1 coil
C0~C79
D0~D399
-
-
Load contact A of X0
Connect to contact B of
Y0 in series
Y1 latch (ON)
C0~C79
D0~D399