Control Mode; Control Of Speed Mode - Delta C2000 series User Manual

Classical field oriented. control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement

Decode Flow Char t
00-08
Password Set
00-07
Password Input
Yes
Pr.00-08=0
No
Re-apply po we r.
(The p assword is still valid)
Reserved

Control Mode

Settings
0: Speed mode
1: Point-to-Point position control
2: Torque mode
3: Home mode
This parameter determines the control mode of C2000 series AC motor drive.

Control of Speed Mode

Settings 0: VF (IM V/f control)
1: VFPG (IM V/f control+ Encoder)
2: SVC(IM sensorless vector control)
3: FOCPG (IM FOC vector control+ encoder)
4: FOCPG(PM FOC vector control + Encoder)
5: FOC Sensorless (IM field oriented sensorless vector control)
6 : PM Sensorless (PM field oriented sensorless vector control)
This parameter determines the control method of the AC motor drive:
0: (IM V/f control): user can design proportion of V/f as required and can control multiple motors
simultaneously.
1: (IM V/f control + Encoder): user can use optional PG card with encoder for the closed-loop
speed control.
2: (IM Sensorless vector control): get the optimal control by the auto-tuning of motor
parameters.
3: (IM FOC vector control+ encoder): besides torque increases, the speed control will be more
accurate (1:1000).
4: (PM FOC vector control + Encoder): besides torque increases, the speed control will be
more accurate (1:1000).
5: FOC Sensorless: IM field oriented sensorless vector control
Chapter 12 Description of Parameter Settings|C2000 Series
Shut down th drive
and re-app ly power
12-6
Factory Setting: 0
Factory Setting: 0