Fujitsu MB91319 Series Hardware Manual page 465

Fr60 32-bit microcontroller
Table of Contents

Advertisement

Table 17.4-1 USB Standard Request Commands and Details of Automatic Responses (2 / 2)
USB standard request command automatically
responded to by this macro program
GET_STATUS
SET_ADDRESS
SET_CONFIGURATI
ON
SET_FEATURE
SET_INTERFACE
Device
End point:
End point number supported
by this macro program
End point:
End point number not
supported by this macro
program
Configuration number
supported by this macro
program
Configuration number not
supported by this macro
program
Device:
DEVICE_REMOTE_WAKEUP
End point:
ENDPOINT_STALL
End point number supported
by this macro program (except
end point 0)
End point:
ENDPOINT_STALL
End point number not
supported by this macro
program or end point 0
Interface or Alternate number
supported by this macro
program
Interface or Alternate number
not supported by this macro
program
CHAPTER 17 USB FUNCTION
Details of automatic response
Data stage
Returns the current
power supply status of
the device and whether
the REMOTE_WAKEUP
function is enabled
Returns the current
status of
ENDPOINT_STALL
Responds with STALL
signal
-
-
-
-
-
-
-
-
Status stage
Receives null data
Receives null data
-
Returns null data
Returns null data
Responds with
STALL signal
Returns null data
Returns null data
Responds with
STALL signal
Returns null data
Responds with
STALL signal
443

Advertisement

Table of Contents
loading

Table of Contents