Display Period Control (Command 14-0, 14-1, 14-2, 14-3) - Fujitsu MB91319 Series Hardware Manual

Fr60 32-bit microcontroller
Table of Contents

Advertisement

18.5.9

Display Period Control (Command 14-0, 14-1, 14-2, 14-3)

Command 14-0, command 14-1, command 14-2, and command 14-3 are the commands
that control the display period.
■ Command 14-0 (Display Period Control 1)
❍ Address: 132
❍ Format
15
14
13
0
0
0
DYS10 - DYS0:
❍ [Function]
This command controls the display beginning timing in the vertical direction.
■ Command14-1 (Display Period Control 2)
❍ Address: 134
❍ Format
15
14
13
0
0
0
DYE10 - DYE0:
❍ [Function]
This command controls the display end timing in the vertical direction.
■ Command14-2 (Display Period Control 3)
❍ Address: 136
H
12
11
10
9
0
0
DYS10 DYS9 DYS8 DYS7 DYS6 DYS5 DYS4 DYS3 DYS2 DYS1 DYS0
Vertical direction display beginning control
(0 to 2047, 1-dot unit)
H
12
11
10
9
0
0
DYE10 DYE9 DYE8 DYE7 DYE6 DYE5 DYE4 DYE3 DYE2 DYE1 DYE0
Vertical direction display end control
(0 to 2047, 1-dot unit)
H
8
7
6
5
8
7
6
5
CHAPTER 18 OSDC
4
3
2
1
4
3
2
1
0
0