Onstant Power Status Register (Cpstat); Onstant Power Status Register (Cpstat) Register Field Descriptions - Texas Instruments UCD3138 Technical Reference Manual

Digital power supply controller
Hide thumbs Also See for UCD3138:
Table of Contents

Advertisement

www.ti.com
5.14.17 Constant Power Status Register (CPSTAT)
Address 00020040
8
7
CONSTANT
CONSTANT
_CUR
_PWR
R-0
R-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 5-18. onstant Power Status Register (CPSTAT) Register Field Descriptions
Bit
Field
8
CONSTANT_CUR
7
CONSTANT_PWR R
6
CONSTANT
_VOLT
5
CC_TO_CV_INT
4
CC_TO_CC_INT
3
CV_TO_CC_INT
2
CC_TO_CP_INT
1
CP_TO_CV_INT
0
CV_TO_CP_INT
SNIU028A – February 2016 – Revised April 2016
Submit Documentation Feedback
Figure 5-18. onstant Power Status Register (CPSTAT)
6
5
CONSTANT
CC_TO_CV
_VOLT
_INT
R-0
R-0
Type
Reset
R
0
Constant Current Mode Indication
0 = Constant Current Mode not enabled
1 = Constant Current Mode enabled
0
Constant Power Mode Indication
0 = Constant Power Mode not enabled
1 = Constant Power Mode enabled
R
0
Constant Voltage Mode Indication
0 = Constant Voltage Mode not enabled
1 = Constant Voltage Mode enabled
R
0
Constant Current Mode to Constant Voltage Mode latched status, cleared on read
0 = No transition from Constant Current to Constant Voltage detected
1 = Transition from Constant Current to Constant Voltage detected
R
0
Constant Voltage Mode to Constant Current Mode latched status, cleared on read
0 = No transition from Constant Voltage to Constant Current detected
1 = Transition from Constant Voltage to Constant Current detected
R
0
Constant Current Mode to Constant Power Mode latched status, cleared on read
0 = No transition from Constant Current to Constant Power detected
1 = Transition from Constant Current to Constant Power detected
R
0
Constant Power Mode to Constant Current Mode latched status, cleared on read
0 = No transition from Constant Power to Constant Current detected
1 = Transition from Constant Power to Constant Current detected
R
0
Constant Power Mode to Constant Voltage Mode latched status, cleared on read
0 = No transition from Constant Power to Constant Voltage detected
1 = Transition from Constant Power to Constant Voltage detected
R
0
Constant Voltage Mode to Constant Power Mode latched status, cleared on read
0 = No transition from Constant Voltage to Constant Power detected
1 = Transition from Constant Voltage to Constant Power detected
Copyright © 2016, Texas Instruments Incorporated
4
3
CC_TO_CC
CV_TO_CC
_INT
_INT
R-0
R-0
Description
Loop Mux Registers Reference
2
1
CC_TO_CP
CP_TO_CV
_INT
_INT
R-0
R-0
Loop Mux
0
CV_TO_CP
_INT
R-0
213

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents