Loop Mux Registers Reference
Table 5-11. Constant Power Control Register (CPCTRL) Register Field Descriptions (continued)
Bit
Field
2
CCPC_INT_EN
1
CPCC_CONFIG
0
CPCC_EN
206
Loop Mux
Type
Reset
R/W
0
Constant Power/Constant Current Interrupt Enable
0 = Interrupt disabled on mode switches (Default)
1 = Interrupt enabled on mode switches
R/W
0
Controls Constant Power/Constant Current module configuration
0 = Average Current Mode (Default)
1 = Constant Power Module controls selection of voltage/current loop
R/W
0
Constant Power Constant/Current Module Enable
0 = Constant Power/Constant Current Module disabled (Default)
1 = Constant Power/Constant Current Module enabled