Filter Registers Reference

4.11.23 Filter Output Clamp High Register (FILTEROCLPHI)

Address 00060058 – Filter 2 Output Clamp High Register
Address 00090058 – Filter 1 Output Clamp High Register
Address 000C0058 – Filter 0 Output Clamp High Register
23
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 4-23. Filter Output Clamp High Register (FILTEROCLPHI) Register Field Descriptions
Bit
Field
23-0
OUTPUT_CLAMP
_HIGH
182
Filter
Figure 4-28. Filter Output Clamp High Register (FILTEROCLPHI)
OUTPUT_CLAMP_HIGH
R/W-11 1111 1111 1111 1111
Type
Reset
R/W
11 1111
Sets the upper limit of filter output value. If calculated filter output exceeds this
1111
threshold, the filter output will be set to OUTPUT_CLAMP_HIGH
1111
1111
Copyright © 2016, Texas Instruments Incorporated