Loop Mux Registers Reference
Table 5-2. Front End Control 0 Mux Register (FECTRL0MUX) Register Field Descriptions (continued)
Bit
Field
9
DPWM1_FRAME_
SYNC_EN
8
DPWM0_FRAME_
SYNC_EN
7
DPWM3_B_TRIG_
EN
6
DPWM2_B_TRIG_
EN
5
DPWM1_B_TRIG_
EN
4
DPWM0_B_TRIG_
EN
3
DPWM3_A_TRIG_
EN
2
DPWM2_A_TRIG_
EN
1
DPWM1_A_TRIG_
EN
0
DPWM0_A_TRIG_
EN
192
Loop Mux
Type
Reset
R/W
0
Enables DPWM Trigger from DPWM 1 Frame Sync to Front End Control
0 = DPWM 1 Frame Sync not routed to Front End Control (Default)
1 = DPWM 1 Frame Sync routed to Front End Control
R/W
0
Enables DPWM Trigger from DPWM 0 Frame Sync to Front End Control
0 = DPWM 0 Frame Sync not routed to Front End Control (Default)
1 = DPWM 0 Frame Sync routed to Front End Control
R/W
0
Enables DPWM Trigger from DPWM 3 PWM-B to Front End Contro
l0 = DPWM 3 PWM-B trigger not routed to Front End Control (Default)
1 = DPWM 3 PWM-B trigger routed to Front End Control
R/W
0
Enables DPWM Trigger from DPWM 2 PWM-B to Front End Control
0 = DPWM 2 PWM-B trigger not routed to Front End Control (Default)
1 = DPWM 2 PWM-B trigger routed to Front End Control
R/W
0
Enables DPWM Trigger from DPWM 1 PWM-B to Front End Control
0 = DPWM 1 PWM-B trigger not routed to Front End Control (Default)
1 = DPWM 1 PWM-B trigger routed to Front End Control
R/W
0
Enables DPWM Trigger from DPWM 0 PWM-B to Front End Control
0 = DPWM 0 PWM-B trigger not routed to Front End Control (Default)
1 = DPWM 0 PWM-B trigger routed to Front End Control
R/W
0
Enables DPWM Trigger from DPWM 3 PWM-A to Front End Control
0 = DPWM 3 PWM-A trigger not routed to Front End Control (Default)
1 = DPWM 3 PWM-A trigger routed to Front End Control
R/W
0
Enables DPWM Trigger from DPWM 2 PWM-B to Front End Control
0 = DPWM 2 PWM-A trigger not routed to Front End Control (Default)
1 = DPWM 2 PWM-A trigger routed to Front End Control
R/W
0
Enables DPWM Trigger from DPWM 1 PWM-B to Front End Control
0 = DPWM 1 PWM-A trigger not routed to Front End Control (Default)
1 = DPWM 1 PWM-A trigger routed to Front End Control
R/W
0
Enables DPWM Trigger from DPWM 0 PWM-B to Front End Control
0 = DPWM 0 PWM-A trigger not routed to Front End Control (Default)
1 = DPWM 0 PWM-A trigger routed to Front End Control