Sample Trigger Control Register (Samptrigctrl); Sample Trigger Control Register (Samptrigctrl) Register Field Descriptions - Texas Instruments UCD3138 Technical Reference Manual

Digital power supply controller
Hide thumbs Also See for UCD3138:
Table of Contents

Advertisement

www.ti.com

5.14.4 Sample Trigger Control Register (SAMPTRIGCTRL)

Address 0002000C
11
FE2_TRIG_DPWM3_EN
R/W-0
7
6
FE1_TRIG_
FE1_TRIG_
DPWM3_EN
DPWM2_EN
R/W-0
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 5-5. Sample Trigger Control Register (SAMPTRIGCTRL) Register Field Descriptions
Bit
Field
11
FE2_TRIG_
DPWM3_EN
10
FE2_TRIG_
DPWM2_EN
9
FE2_TRIG_
DPWM1_EN
8
FE2_TRIG_
DPWM0_EN
7
FE1_TRIG_
DPWM3_EN
6
FE1_TRIG_
DPWM2_EN
5
FE1_TRIG_
DPWM1_EN
4
FE1_TRIG_
DPWM0_EN
3
FE0_TRIG_
DPWM3_EN
2
FE0_TRIG_
DPWM2_EN
1
FE0_TRIG_
DPWM1_EN
0
FE0_TRIG_
DPWM0_EN
SNIU028A – February 2016 – Revised April 2016
Submit Documentation Feedback
Figure 5-5. Sample Trigger Control Register (SAMPTRIGCTRL)
10
FE2_TRIG_DPWM2_EN
R/W-0
5
4
FE1_TRIG_
FE1_TRIG_
DPWM1_EN
DPWM0_EN
R/W-0
R/W-0
Type
Reset
R/W
0
Enables Sample Trigger from DPWM 3 to Front End Control 2
0 = DPWM 3 Sample Trigger not routed to Front End Control 2 (Default)
1 = DPWM 3 Sample Trigger routed to Front End Control 2
R/W
0
Enables Sample Trigger from DPWM 2 to Front End Control 2
0 = DPWM 2 Sample Trigger not routed to Front End Control 2 (Default)
1 = DPWM 2 Sample Trigger routed to Front End Control 2
R/W
0
Enables Sample Trigger from DPWM 1 to Front End Control 2
0 = DPWM 1 Sample Trigger not routed to Front End Control 2 (Default)
1 = DPWM 1 Sample Trigger routed to Front End Control 2
R/W
0
Enables Sample Trigger from DPWM 0 to Front End Control 2
0 = DPWM 0 Sample Trigger not routed to Front End Control 2 (Default)
1 = DPWM 0 Sample Trigger routed to Front End Control 2
R/W
0
Enables Sample Trigger from DPWM 3 to Front End Control 1
0 = DPWM 3 Sample Trigger not routed to Front End Control 1 (Default)
1 = DPWM 3 Sample Trigger routed to Front End Control 1
R/W
0
Enables Sample Trigger from DPWM 2 to Front End Control 1
0 = DPWM 2 Sample Trigger not routed to Front End Control 1 (Default)
1 = DPWM 2 Sample Trigger routed to Front End Control 1
R/W
0
Enables Sample Trigger from DPWM 1 to Front End Control 1
0 = DPWM 1 Sample Trigger not routed to Front End Control 1 (Default)
1 = DPWM 1 Sample Trigger routed to Front End Control 1
R/W
0
Enables Sample Trigger from DPWM 0 to Front End Control 1
0 = DPWM 0 Sample Trigger not routed to Front End Control 1 (Default)
1 = DPWM 0 Sample Trigger routed to Front End Control 1
R/W
0
Enables Sample Trigger from DPWM 3 to Front End Control 0
0 = DPWM 3 Sample Trigger not routed to Front End Control 0 (Default)
1 = DPWM 3 Sample Trigger routed to Front End Control 0
R/W
0
Enables Sample Trigger from DPWM 2 to Front End Control 0
0 = DPWM 2 Sample Trigger not routed to Front End Control 0 (Default)
1 = DPWM 2 Sample Trigger routed to Front End Control 0
R/W
0
Enables Sample Trigger from DPWM 1 to Front End Control 0
0 = DPWM 1 Sample Trigger not routed to Front End Control 0 (Default)
1 = DPWM 1 Sample Trigger routed to Front End Control 0
R/W
0
Enables Sample Trigger from DPWM 0 to Front End Control 0
0 = DPWM 0 Sample Trigger not routed to Front End Control 0 (Default)
1 = DPWM 0 Sample Trigger routed to Front End Control 0
Copyright © 2016, Texas Instruments Incorporated
9
FE2_TRIG_DPWM1_EN
R/W-0
3
2
FE0_TRIG_
FE0_TRIG_
DPWM3_EN
DPWM2_EN
R/W-0
R/W-0
Description
Loop Mux Registers Reference
8
FE2_TRIG_DPWM0_EN
R/W-0
1
0
FE0_TRIG_
FE0_TRIG_
DPWM1_EN
DPWM0_EN
R/W-0
R/W-0
Loop Mux
197