Constant Power Max Threshold Register (Cpmax); Constant Power Max Threshold Register (Cpmax) Register Field Descriptions - Texas Instruments UCD3138 Technical Reference Manual

Digital power supply controller
Hide thumbs Also See for UCD3138:
Table of Contents

Advertisement

Loop Mux Registers Reference

5.14.12 Constant Power Max Threshold Register (CPMAX)

Address 0002002C
25
MAX_CURRENT_UPPER
R/W-00 0000 0000
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 5-13. Constant Power Max Threshold Register (CPMAX) Register Field Descriptions
Bit
Field
25-16
MAX_CURRENT_
UPPER
15-10
Reserved
9-0
MAX_CURRENT_
LOWER
208
Loop Mux
Figure 5-13. Constant Power Max Threshold Register (CPMAX)
16
15
Type
Reset
R/W
00 0000
Configures IMAX value used in Constant Power/Constant Current Calculations, when
0000
sensed value exceeds MAX_CURRENT_UPPER in Constant Power mode, setpoint
will switch to Max Current mode
R
00 0000
R/W
00 0000
Configures IMAX value used in Constant Power/Constant Current Calculations, when
0000
sensed value falls below MAX_CURRENT_LOWER in Max Current mode, setpoint
will switch to Constant Power mode
Copyright © 2016, Texas Instruments Incorporated
10
Reserved
R-00 0000
Description
SNIU028A – February 2016 – Revised April 2016
www.ti.com
9
MAX_CURRENT_LOWER
R/W-00 0000 0000
Submit Documentation Feedback
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents