Table 4-1. Filter Status Register (FILTERSTATUS) Register Field Descriptions
Bit
Field
4
FILTER_BUSY
3
YN_LOW_CLAMP
2
YN_HIGH_
CLAMP
1
KI_YN_LOW_
CLAMP
0
KI_YN_HIGH_CLA
MP
SNIU028A – February 2016 – Revised April 2016
Submit Documentation Feedback
Type
Reset
R
0
Filter Busy Indicator
0 = Filter is waiting for new data
1= Filter busy calculating
R
0
PID Output Low Rail Indicator
0 = PID Output not equal to low rail
1 = PID Output equal to low rail
R
0
PID Output High Rail Indicator
0 = PID Output not equal to high rail
1 = PID Output equal to high rail
R
0
KI Feedback Low Rail Indicator
0 = KI Feedback not equal to low rail
1 = KI Feedback equal to low rail
R
0
KI Feedback High Rail Indicator
0 = KI Feedback not equal to high rail
1 = KI Feedback equal to high rail
Copyright © 2016, Texas Instruments Incorporated