Front End Control 2 Mux Register (Fectrl2Mux); Front End Control 2 Mux Register (Fectrl2Mux) Register Field Descriptions - Texas Instruments UCD3138 Technical Reference Manual

Digital power supply controller
Hide thumbs Also See for UCD3138:
Table of Contents

Advertisement

www.ti.com

5.14.3 Front End Control 2 Mux Register (FECTRL2MUX)

Address 00020008
13
NL_SEL
R/W-00
7
6
DPWM3_B_
DPWM2_B_
TRIG_EN
TRIG_EN
R/W-0
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 5-4. Front End Control 2 Mux Register (FECTRL2MUX) Register Field Descriptions
Bit
Field
13-12
NL_SEL
11
DPWM3_FRAME_
SYNC_EN
10
DPWM2_FRAME_
SYNC_EN
9
DPWM1_FRAME_
SYNC_EN
8
DPWM0_FRAME_
SYNC_EN
7
DPWM3_B_TRIG_
EN
6
DPWM2_B_TRIG_
EN
5
DPWM1_B_TRIG_
EN
4
DPWM0_B_TRIG_
EN
3
DPWM3_A_TRIG_
EN
2
DPWM2_A_TRIG_
EN
SNIU028A – February 2016 – Revised April 2016
Submit Documentation Feedback
Figure 5-4. Front End Control 2 Mux Register (FECTRL2MUX)
12
11
DPWM3_FRAME_
SYNC_EN
R/W-0
5
4
DPWM1_B_
DPWM0_B_
TRIG_EN
TRIG_EN
R/W-0
R/W-0
Type
Reset
R/W
00
Configures source of Non-Linear (NL) comparison results used in Automatic Gain
Shifting
0 = Filter 0 NL Results used
1 = Filter 1 NL Results used
2 = Filter 2 NL Results used (Default)
R/W
0
Enables DPWM Trigger from DPWM 3 Frame Sync to Front End Control
0 = DPWM 3 Frame Sync not routed to Front End Control (Default)
1 = DPWM 3 Frame Sync routed to Front End Control
R/W
0
Enables DPWM Trigger from DPWM 2 Frame Sync to Front End Control
0 = DPWM 2 Frame Sync not routed to Front End Control (Default)
1 = DPWM 2 Frame Sync routed to Front End Control
R/W
0
Enables DPWM Trigger from DPWM 1 Frame Sync to Front End Control
0 = DPWM 1 Frame Sync not routed to Front End Control (Default)
1 = DPWM 1 Frame Sync routed to Front End Control
R/W
0
Enables DPWM Trigger from DPWM 0 Frame Sync to Front End Control
0 = DPWM 0 Frame Sync not routed to Front End Control (Default)
1 = DPWM 0 Frame Sync routed to Front End Control
R/W
0
Enables DPWM Trigger from DPWM 3 PWM-B to Front End Control
0 = DPWM 3 PWM-B trigger not routed to Front End Control (Default)
1 = DPWM 3 PWM-B trigger routed to Front End Control
R/W
0
Enables DPWM Trigger from DPWM 2 PWM-B to Front End Control
0 = DPWM 2 PWM-B trigger not routed to Front End Control (Default)
1 = DPWM 2 PWM-B trigger routed to Front End Control
R/W
0
Enables DPWM Trigger from DPWM 1 PWM-B to Front End Control
0 = DPWM 1 PWM-B trigger not routed to Front End Control (Default)
1 = DPWM 1 PWM-B trigger routed to Front End Control
R/W
0
Enables DPWM Trigger from DPWM 0 PWM-B to Front End Control
0 = DPWM 0 PWM-B trigger not routed to Front End Control (Default)
1 = DPWM 0 PWM-B trigger routed to Front End Control
R/W
0
Enables DPWM Trigger from DPWM 3 PWM-A to Front End Control
0 = DPWM 3 PWM-A trigger not routed to Front End Control (Default)
1 = DPWM 3 PWM-A trigger routed to Front End Control
R/W
0
Enables DPWM Trigger from DPWM 2 PWM-B to Front End Control
0 = DPWM 2 PWM-A trigger not routed to Front End Control (Default)
1 = DPWM 2 PWM-A trigger routed to Front End Control
Copyright © 2016, Texas Instruments Incorporated
10
DPWM2_FRAME_
DPWM1_FRAME_
SYNC_EN
SYNC_EN
R/W-0
R/W-0
3
2
DPWM3_A_
DPWM2_A_
TRIG_EN
TRIG_EN
R/W-0
R/W-0
Description
Loop Mux Registers Reference
9
8
DPWM0_FRAME_
SYNC_EN
R/W-0
1
0
DPWM1_A_
DPWM0_A_
TRIG_EN
TRIG_EN
R/W-0
R/W-0
Loop Mux
195

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents